LIFEPAK CR Plus Semi Automatic AED Defibrillator 5005001
• Semi-Automatic Operation
• Portable and Lightweight
• Clear Verbal Instructions
• 5 Year Warranty
See More.....
|
More Items To Consider
Product Specification
- Product Code
- HA5005001
- Manufacturer Ref
- 5005001
- Type
- Semi Automatic
- Battery Standby Life
- 2 Years
- Brand
- Lifepak
- Pack Type
- Standard Pack
Product Details
- LIFEPAK CR Plus Semi Automatic AED Defibrillator 5005001
- CHARGE-PAK Battery Charger
- Type: Li/SO2Cl2 Lithium Sulfuryl Chloride, 11.7V, 1.4 amp-hours.
- Replacement: Replace the CHARGE-PAK battery charger and QUIK-PAK™ electrodes packet after using the defibrillator, if the CHARGE-PAK symbol appears in the readiness display or when the Use by date is reached (typically 2 years).
- Weight: 80.5 grams (0.18 lb).
- Pads: ECG is received from disposable defibrillation electrodes, standard placement (anterior-lateral).
- Pads Packaging: User intuitive, rapid release Quik-Pak electrodes allow the electrode pads to be preconnected to the device and protected under a top cover.
- Pads Replacement: Replace every two (2) years.
- Infant/Child Reduced Energy Defibrillation Electrodes: For use on infants and children less than 8 years of age or less than 55 lbs (25kg).
- Waveform: Biphasic truncated exponential, with voltage and current duration compensation for patient impedance.*
- Output Energy Sequence: Multiple levels, configurable from 150 joules to 360 joules (200 joules min for Japan). Factory default settings of 200J, 300J, 360J.
- Output Energy Accuracy: ±10% into 50 ohms, ±15% into 25 to 100 ohms.
- Shock Advisory System: An ECG analysis system that advises whether a shock is appropriate; meets rhythm recognition criteria specified in DF39. The device charges for shock only when the Shock Advisory System advises defibrillation.
- Memory Type: Internal digital memory.
- ECG Storage: Dual patient data storage. Minimum 20 minutes of ECG stored for the current patient, summarized data stored for the previous patient.
- Report Types:
- Continuous ECG – A continuous patient ECG report.
- Continuous Summary report – A summary of critical resuscitation events and ECG waveform segments associated with these events.
- Event Log report – A report of time stamped markers, which reflect operator and device activity.
- Test Log report – A device self-test activity report.
- Capacity: Minimum 200 time-stamped event log markers.
- Communications: Wireless transfer to a personal computer.
- Data Review: Physio-Control provides an array of tools to meet customer needs for data viewing and analysis.
- * The specifications apply from 25 to 200 ohms. Voltage compensation is limited to the voltage that would result in delivery of 360 joules into 50 ohms.