LIFEPAK CR Plus Automatic External AED Defibrillator - designed for safe and easy use by a lay rescuer - clear, calm, step-by-step instructions - 5005002
- Physio-Control’s reputation—and mission—is built on confidence.
The confidence that comes from over 50 years of innovation, a steadfast commitment to quality, and a position as the global leader in defibrillation. The confidence that comes from manufacturing the lifesaving equipment of choice for more EMS and hospital units around the world than any other brand. The confidence that comes from knowing that the LIFEPAK CR Plus defibrillator in your office, the airport, or your child’s school can simply, safely, and effectively help someone save a life. - QUIK-PAK Electrode Pads
Pads: ECG is received from disposable defibrillation electrodes, standard placement (anterior-lateral).
Pads Packaging: User intuitive, rapid release Quik-Pak electrodes allow the electrode pads to be preconnected to the device and protected under a top cover.
Pads Replacement: Replace every two (2) years.
Infant/Child Reduced Energy Defibrillation Electrodes: For use on infants and children less than 8 years of age or less than 55 lbs (25kg). - Defibrillator
Waveform: Biphasic truncated exponential, with voltage and current duration compensation for patient impedance.
Output Energy Sequence: Multiple levels, configurable from 150 joules to 360 joules (200 joules min for Japan). Factory default settings of 200J, 300J, 360J.
Output Energy Accuracy: ±10% into 50 ohms, ±15% into 25 to 100 ohms.
Shock Advisory System: An ECG analysis system that advises whether a shock is appropriate; meets rhythm recognition criteria specified in DF39. The device charges for shock only when the Shock Advisory System advises defibrillation.
|
More Items To Consider
Product Specification
- Product Code
- HA5005002
- Manufacturer Ref
- 5005002
- Type
- Fully Automatic
- Battery Standby Life
- 2 Years
- Brand
- Lifepak
- Pack Type
- Standard Pack
Product Details
- LIFEPAK CR Plus Automatic External AED Defibrillator - designed for safe and easy use by a lay rescuer - clear, calm, step-by-step instructions - 5005002
- CHARGE-PAK Battery Charger
- Type: Li/SO2Cl2 Lithium Sulfuryl Chloride, 11.7V, 1.4 amp-hours.
- Replacement: Replace the CHARGE-PAK battery charger and QUIK-PAK™ electrodes packet after using the defibrillator, if the CHARGE-PAK symbol appears in the readiness display or when the Use by date is reached (typically 2 years).
- Weight: 80.5 grams (0.18 lb).
- Pads: ECG is received from disposable defibrillation electrodes, standard placement (anterior-lateral).
- Pads Packaging: User intuitive, rapid release Quik-Pak electrodes allow the electrode pads to be preconnected to the device and protected under a top cover.
- Pads Replacement: Replace every two (2) years.
- Infant/Child Reduced Energy Defibrillation Electrodes: For use on infants and children less than 8 years of age or less than 55 lbs (25kg).
- Waveform: Biphasic truncated exponential, with voltage and current duration compensation for patient impedance.*
- Output Energy Sequence: Multiple levels, configurable from 150 joules to 360 joules (200 joules min for Japan). Factory default settings of 200J, 300J, 360J.
- Output Energy Accuracy: ±10% into 50 ohms, ±15% into 25 to 100 ohms.
- Shock Advisory System: An ECG analysis system that advises whether a shock is appropriate; meets rhythm recognition criteria specified in DF39. The device charges for shock only when the Shock Advisory System advises defibrillation.
- Memory Type: Internal digital memory.
- ECG Storage: Dual patient data storage. Minimum 20 minutes of ECG stored for the current patient, summarized data stored for the previous patient.
- Continuous ECG – A continuous patient ECG report.
- Continuous Summary report – A summary of critical resuscitation events and ECG waveform segments associated with these events.
- Event Log report – A report of time stamped markers, which reflect operator and device activity.
- Test Log report – A device self-test activity report.
- Capacity: Minimum 200 time-stamped event log markers.
- Communications: Wireless transfer to a personal computer.
- Data Review: Physio-Control provides an array of tools to meet customer needs for data viewing and analysis.
- * The specifications apply from 25 to 200 ohms. Voltage compensation is limited to the voltage that would result in delivery of 360 joules into 50 ohms.