LIFEPAK 1000 AED Semi Automatic External Defibrillator ECG and Manual Mode
- Semi Automatic Operation
- Provides ECG display capability with 3-wire ECG cable.
- CPR Countdown Timer
- 5 Year Battery
|
More Items To Consider
Product Specification
- Product Code
- H44084006
- Pack Size
- Single Pack
- Manufacturer Ref
- 99425-000096
- Alternative Code(s)
- 5005004
- Type
- Semi Automatic with ECG Display
- Battery Standby Life
- 5 Years
- Brand
- Lifepak
- Pack Type
- Standard Pack
Product Details
- LIFEPAK 1000 AED Semi Automatic External Defibrillator ECG and Manual Mode
Easy-To-Use AED - Loud voice prompts and on-screen graphics provide guidance
on applying electrodes and initiating a shock.
DEVICE SETTINGS
Modes:
AED – Provides operating capability for basic users.
Manual –
Provides operating capability for advanced users.
ECG – Provides ECG display
capability with 3-wire ECG cable.
Setup – Allows user to configure the
device.
Data Transfer – Allows user to transfer patient data.
Auto Test –
Provides daily automatic tests of hardware and software.
Controls:
On/Off, Shock, Menu, Two (2) configurable soft keys.
User Defined
Options:
Device ID – Assigns unique identifier to particular device.
Energy Sequence – User configurable from 150 to 360 joules.
Flexible Energy –
Increases only after a lower energy was unsuccessful.
Auto Analyze – User can
configure device to auto analyze, auto analyze after first shock, or prompt user
to push analyze key before each analysis period.
CPR Time – (Post shock or
after no shock advised) – User configurable – 15, 30, 45, 60, 90, 120, 180
seconds.
Device Date/Time
Voice Prompt Volume – Allows user to change
speaker volume.
ECG Display – (If option purchased) – Turns display on/off
for AED mode.
Motion Detection – User defined On/Off (default On).
Service
Alert – Audio alarm if the device needs servicing. Configurable on/off.
Manual Access – (If ECG display option purchased) – Devices configured with an
ECG display may be set up to allow user to initiate a charge and shock without
analysis.
cprMAX Technology Settings:
Initial CPR – User defined time for
CPR after first analysis regardless of analysis decision. Can be set to OFF, 15,
30, 45, 60, 90, 120 and 180 seconds.
Pre-shock CPR – Allows for CPR while
device is charging. Can be set to OFF, 15, or 30 seconds.
Stacked Shocks –
(ON/OFF) When Off, allows for provision of CPR after each shock.
Pulse Check
– (Always, After Every NSA, After Second NSA, Never) Allows device to prompt for
a pulse check either after each shock, after every NSA pulse check, or never
prompt for a pulse check (default Never)
PHYSICAL CHARACTERISTICS
Height: 8.7 cm (3.4 in).
Width: 23.4 cm (9.2 in).
Depth: 27.7 cm (10.9
in).
Weight: 3.2 kg (7.1 lbs) with one set of REDI-PAK electrodes and one
non-rechargeable battery
AED users should be trained in CPR and use of the
AED.